Ludlums - Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh …

 
LudlumsLudlums - Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ...

The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS (Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. …Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672 Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. Temperature dependent. Drop Resistance. Survives 100g drops in three orientations. Size (H x W x L) 25.7 x 10.8 x 10.8 cm (10.125 x 4.25 x 4.25 in.) Weight. 2.2 kg (5 lb) Note: For gamma backgrounds greater than 100 mR/h, we recommend using Model 42-31H. Model. Ludlum Measurements, Inc. (LMI) designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and ... Features. The Model 9DP is a digital, hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Measurements and instrument status are displayed on a large, 232K-color, backlit LCD screen.Contact Information. You may Call, Fax, E-mail, or Mail your order to the following: LUDLUM MEASUREMENTS, INC. P.O. Box 810. Sweetwater, Texas 79556. PHONE: 800-622-0828 (USA and Canada) or 325-235-5494. FAX: 325-235-4672. E-MAIL: The privacy policy for the Ludlum Measurements website.Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ...Bourne are a series of three novels by Robert Ludlum based on the fictional spy Jason Bourne.The series has since been further extended by Eric Van Lustbader after the …Alpha. All our instruments and detectors come standard with series "C" connectors. However, other connectors are available if specifically requested when ordering your instrument. View a list of common connectors. Detector Reference Chart. Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment.When contacting us through email, please remember to fill in the "Subject" line so that we can quickly assess your needs. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Office Hours: 8:00 am - 5:00 pm CST, Monday - Friday. Toll Free: 800-622-0828 (US & Canada) Tel: 325-235-5494. Fax: 325-235-4672.The Model 44-40 Series are shielded GM (Geiger-Mueller) detectors capable of detecting alpha, beta, or gamma radiation. Both the Model 44-40 and 44-40-2 have lead shielding. The Model 44-40 has a painted lead …The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ...Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website.Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] Of his twenty-seven novels, two were originally published under the pseudonym of Jonathan Ryder and another under the pseudonym of Michael Shepherd.The Model 44-1 is a plastic scintillator detector for measuring beta radiation. It has a 9.7 cm 2 (1.5 in 2 ) active window area.Robert Ludlum was the author of twenty-seven novels, each one a New York Times bestseller. There are more than 210 million of his books in print, and they have been translated into thirty-two languages. He is the author of The Scarlatti Inheritance, The Chancellor Manuscript, and the Jason Bourne series--The Bourne Identity, The Bourne ...The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away.The Model 193-6 is a highly sensitive gamma microR survey meter with an extended reach capability. A very sensitive 15.2 x 2.5 cm thick (6 x 1 in.) plastic scintillator detector is mounted at the end of a 1.2 m (4 ft) long pole to facilitate reaching elevated areas. Attached to the user-end of the pole is a four-range analog ratemeter employing ...The Model 44-110-4 is a sample counter head with a windowless gas proportional detector for measuring alpha and beta radiation. It can hold samples up to 5.1 cm (2 in.) dia.The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ... The Ludlum Model 44-172 YSO (Yttrium Oxyorthosilicate) detector is used primarily for the detection of low-energy gamma radiation, from approximately 5 keV to 145 keV. It will also detect beta energy as low as 49 keV. The detector consists of a 2.5 cm (1 in.) diameter by 1 mm (0.04 in.) thick YSO scintillator. The window area is approximately 5 ... The Model 3001-2RK is composed of two dependable, high-quality detectors matched with the versatile Model 3001 survey meter and packaged in a rugged transport and storage case. The Model 3001 can be configured with up to four detector setups, enabling the user to quickly exchange detectors in the field. Once the detector system is configured, a ... Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ... Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Temperature dependent. Drop Resistance. Survives 100g drops in three orientations. Size (H x W x L) 25.7 x 10.8 x 10.8 cm (10.125 x 4.25 x 4.25 in.) Weight. 2.2 kg (5 lb) Note: For gamma backgrounds greater than 100 mR/h, we recommend using Model 42-31H. Model.The Model 2000 is a general purpose scaler typically used for counting samples. Rugged design and construction accommodates both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2000 supports GM, proportional, and scintillator type ... Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ... The Model 3101 Tritium in Air Monitor features ruggedized and flexible operation. It is powered by rechargeable internal NiMH batteries and/or an external +12 Vdc power supply. It features a maintenance-free diaphragm air pump to pull air through the 250 cc tritium chamber, and the air flow is measured internally with a mass-air flow sensor.The Model 53 Gamma Personnel Portal detects gamma radiation in or on personnel passing through the portal from either direction. This highly sensitive portal uses eight large plastic scintillation detectors. Shielding is accomplished with either the standard 2.5 cm (1 in.) or optional 5.1 cm (2 in.) thickness of lead.The Model 3006 is a portable and versatile instrument with extended reach used for gamma or X-ray radiation survey. A sensitive plastic scintillator detector is mounted at the end of a 118 cm (46.5 in.) pole for ease of use when surveying trucks, scrap metal, or other items/areas of concern. It features a large, easy-to-read LCD screen and ...The Model 3006 is a portable and versatile instrument with extended reach used for gamma or X-ray radiation survey. A sensitive plastic scintillator detector is mounted at the end of a 118 cm (46.5 in.) pole for ease of use when surveying trucks, scrap metal, or other items/areas of concern. It features a large, easy-to-read LCD screen and ...The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, …Part Number: 2002-1050. Ludlum offers an energy compensation filter that flattens the energy response of our popular Model 44-9 GM pancake detector and Model 26-Series friskers to facilitate measuring Ambient Equivalent Dose (Sieverts). The venerable GM pancake has a significant over-response at lower energies between approximately 20 to …Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672 Mar 15, 2024 · The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason Bourne was an unforgettable agent in the top-secret CIA Black Ops program, Operation Treadstone. Now, author Joshua Hood has created a new protégé, Adam Hayes. When an Ludlum Model 3 survey meter is ordered with a Model 44-9 pancake GM detector and the customer requests a dual scale mR/hr and cpm meter face, we would send a 202-608 meter face. However, if the customer ordered at Model 44-6, sidewall GM detector, we would send a 202-241. A list of meter scales and compatible detectors are listed on the ... This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number. The Model 44-88 is a pancake GM detector for measuring alpha, beta, and gamma radiation. It has a 15 cm 2 (2.3 in 2 ) active window area.Alpha-Beta Gas Proportional Detector. The Models 43-37 and 43-37-1 are large-area gas proportional detectors for alpha and beta survey. Originally designed to be used with the Model 239-1 Floor Monitor, both detectors are compatible with a number of counting instruments. P-10 (10% methane, 90% argon).The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away. External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below). The 2241-2RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the digital, auto-ranging, and versatile Model 2241-2 Scaler-Ratemeter that can measure exposure, contamination, and samples. Shipping Address. All instruments requiring service should be shipped to the following address: Ludlum Measurements, Inc. Attn: Service Department. 501 Oak Street. Sweetwater, TX 79556. USA. The Model 44-3 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 5 cm 2 (0.8 in 2 ) active window area. The Model 182 Radon Flask Counter is a light-tight sample box that uses scintillation techniques for the detection of radiation material. It consists of a light-tight cylindrical well, a two-inch photomultiplier tube (PMT) optically coupled to a light pipe, and an automatic high voltage On-Off switch. During sample counting the radon flask is ... The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, networkability, battery backup, and various options such as remote indicators, printers, relays, and more. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. Features. This intrinsically safe general purpose ratemeter is patterned after Ludlum's best-selling Model 3. It was designed and tested to USA standards for intrinsic safety, permitting it to be used in potentially explosive atmospheres. The Model 3-IS can only be used with select detectors to sustain the intrinsic safety rating.Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] Of his twenty-seven novels, two were originally published under the pseudonym of Jonathan Ryder and another under the pseudonym of Michael Shepherd.The Model 43-9 is a sample counter head with a ZnS(Ag) scintillator detector for measuring alpha radiation. It can hold samples up to 2.5 cm (1 in.) dia.Features. The Model 2221 is a general purpose ratemeter and scaler with an analog display for optimally viewing the count rate and rate of change through all possible four decades of display. It is accompanied by a digital LCD, which can present either the ratemeter data or the scaler counts. Control functions available include: decade range ...Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and …Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the …Indicated Use. Tritium surface survey / Windowless beta survey. Designed to be placed on a flat surface and then purged with P-10 gas for 20 seconds before counting. Detector Type. Gas flow proportional. Window. Windowless. Window Area. Active: 126 cm 2 (19.5 in 2)The Model 44-17 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 17.8 cm 2 (2.8 in 2 ) active window area.The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason …The Model 44-20 is a NaI(Tl) scintillator detector for measuring gamma radiation. It has a 137 Cs sensitivity of 2300 cpm per μR/hr. The GM pancake-type detector in the Model 44-9 is one of the most popular radiation detectors used throughout the world. This alpha, beta, and gamma radiation detector has a rugged metal housing and is conveniently shaped and sized for checking contamination on people and objects. This detector operates between 850 to 1000 volts, and is ... The Ludlum Model 23 mrem Electronic Personal Dosimeter (EPD) is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is ...Indoor/Outdoor Use. Model 375-30. Two 7.6 x 2.5 cm (3 x 1 in.) (Dia x L) NaI (Tl) Scintillator Detectors. Lead Shielding. Indoor/Outdoor Use. Model 375P-336 Series. Two 2753 cm 3 (168 in 3) Plastic Scintillator Detectors. Range: 0 to 9999 kcps. Indoor or Outdoor Use Depending on Model. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. By Richard Sandomir. July 30, 2007. Robert Ludlum died six years ago, but that has done nothing to slow the release of books published under the name of the actor-turned …The Model 182 Radon Flask Counter is a light-tight sample box that uses scintillation techniques for the detection of radiation material. It consists of a light-tight cylindrical well, a two-inch photomultiplier tube (PMT) optically coupled to a light pipe, and an automatic high voltage On-Off switch. During sample counting the radon flask is ...The Model 3002 is a durable, lightweight instrument designed for alpha and beta radiation survey with an external detector. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash resistant construction allows the instrument ...Model 43-44-1 Alpha Detector - Ludlum Measurements Inc. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information. (800) 622-0828 (US, CA) (325) 235-5494. (325) 235-4672. After Hours Tech Support. For 375P & 4525 Series: (800) 717-9506. To search products by model number ...The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason …The Model 3078 Series Stretch Scopes are designed to survey areas for gamma radiation while maintaining distance from potentially high radiation fields. These instruments include external GM detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types ...The cable-less Model 26 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard 15.51 cm 2 GM pancake probe, loud audio “click” output, and …User-Selectable Internal and External Detectors. Ludlum's Model 3-98 is uniquely configured to optimize measurements for 125 I and any alpha, beta, or gamma contamination. The dual detector design allows the user to select the detector for the task at hand. The internally-housed GM pancake detector can be used to measure gamma.When an Ludlum Model 3 survey meter is ordered with a Model 44-9 pancake GM detector and the customer requests a dual scale mR/hr and cpm meter face, we would send a 202-608 meter face. However, if the customer ordered at Model 44-6, sidewall GM detector, we would send a 202-241. A list of meter scales and compatible detectors are listed on the ...6 LiI Scintillator. 45 cpm per mrem/hr. Thermal to 12 MeV. Model 42-41L. PRESCILA Proton Recoil Scintillator. 350 cpm per mrem/hr. Thermal to 100 MeV. Model 42-38 WENDI-2. 3 He Tube.The Model 44-40 Series are shielded GM (Geiger-Mueller) detectors capable of detecting alpha, beta, or gamma radiation. Both the Model 44-40 and 44-40-2 have lead shielding. The Model 44-40 has a painted lead …These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25 Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range.Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh local produce”!The Model 44-7 is an end window GM detector for measuring alpha, beta, and gamma radiation. It has a 6 cm 2 (0.93 in 2 ) active window area.City of san rafael, Orion grill, Tiny thai food, Araglegal, Hearts nashville, Iowa ortho, Monroe township middlesex county, Iron masters, Hear usa, Gilbert garcia, John foggerty, A x armani exchange, King george inn bristol, Front royal warren county

The Model 44-94 is a pancake GM detector for measuring alpha, beta, and gamma radiation. It has a 62 cm 2 (9.6 in 2 ) active window area.. Puking ball

Ludlumschewbacchus

Metal Recycling Catalog. This catalog presents all instrumentation to detect, locate and identify threatening radioactive sources that might find their way into the scrap metal yards. To receive the print version, request PN: 03-6020. The privacy policy for the Ludlum Measurements website.The Ludlum Model 30-4 joins the Model 30 digital display unit with a 22.9 cm (9 in.) REM ball containing a 3 He detector, thereby providing a significant weight reduction and more compact, maneuverable instrument for determining neutron dose rates.Three modes of operation – RATE, MAX, and COUNT – are available for the user.Ludlum Measurements, Inc. (LMI) designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum, we offer a large array of …The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...Indicated Use. Tritium surface survey / Windowless beta survey. Designed to be placed on a flat surface and then purged with P-10 gas for 20 seconds before counting. Detector Type. Gas flow proportional. Window. Windowless. Window Area. Active: 126 cm 2 (19.5 in 2)The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...Plastic Disk Check Sources. These are general purpose check sources used freely to check responses from multiple instruments, or may be contained inside Ludlum's mechanical check source holder that is attached directly to an instrument for convenience. The sources are sealed within a plastic disk. Sources.Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... The Ludlum Model 23 mrem Electronic Personal Dosimeter (EPD) is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is ... Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support …The Model 44-110-4 is a sample counter head with a windowless gas proportional detector for measuring alpha and beta radiation. It can hold samples up to 5.1 cm (2 in.) dia.Convenient In-Field Detector Switching. All of the basic radiation measurement tools likely required to rapidly react to a radiological emergency are conveniently assembled in the Model 2241-3RK2 Response Kit. The digital, auto-ranging Model 2241-3 scaler-ratemeter stores 4 parameter setups to allow for quick detector changes in the field. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. The Model 44-94 is a pancake GM detector for measuring alpha, beta, and gamma radiation. It has a 62 cm 2 (9.6 in 2 ) active window area.Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh …The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, …Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportLudlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum. The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS (Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. This combined system supplies independent backlit LCD readouts to support discriminated alpha and beta sample counting. The Model 44-17 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 17.8 cm 2 (2.8 in 2 ) active window area.The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence.Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] Of his twenty-seven novels, two were originally published under the pseudonym of Jonathan Ryder and another under the pseudonym of Michael Shepherd.The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away.Model 43-44-1 Alpha Detector - Ludlum Measurements Inc. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information. (800) 622-0828 (US, CA) (325) 235-5494. (325) 235-4672. After Hours Tech Support. For 375P & 4525 Series: (800) 717-9506. To search products by model number ... The Model HBP-29 is a whole-body contamination monitor designed to measure personnel leaving controlled areas. Standard features include: 29 beta plastic detectors with semiconductor readout. Stainless steel housing for easy cleaning and durability. Ergonomic detector positioning. Hand-detector on the side. Integrated 17 in. touch-screen display. This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number. Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ... Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh …Includes up to 12 gas proportional or scintillation detectors for surveying large areas mounted on a roll-around cart. Configurations: Model 240 Gas Proportional Floor and Wall Monitor. Model 240S Scintillation Floor and Wall Monitor. Model 240-1 Gas Proportional Floor Monitor. Model 240S-1 Scintillation Floor Monitor. 48-3956. Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ... The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ... This gamma/neutron survey meter combines Ludlum Model 2363 survey meter with the Model 42-41L PRESCILA neutron detector. The gamma detector is an energy compensated GM housed internally to the survey meter. The neutron detector is a proton recoil type, which provides excellent measurement results at less weight than the more traditional REM balls. Features. Integrated, Lightweight Ergonomic Design. High-Impact Plastic with Water-Resistant Rubber Seals. Employs Standard 15.51 cm 2 GM Pancake Detector. Displays in mR/hr, µSv/h, dpm, Bq, cpm, or cps. Dead-Time Correction (DTC) Allows Gamma Measurements Up to 500 mR/hr or Up to 1999 µSv/h. Simple Three-Button Operation. The Model 44-7 is an end window GM detector for measuring alpha, beta, and gamma radiation. It has a 6 cm 2 (0.93 in 2 ) active window area.Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging.The Model 43-92 is a ZnS(Ag) scintillator detector for measuring alpha radiation. It has a 100 cm 2 (15.5 in 2 ) active window area.The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason …The Model 375P-336 Series are monitoring systems that consist of a Model 375P digital controller coupled with two lead shielded 2753 cm 3 (168 in 3) plastic scintillation detectors. The Model 375P-336 is designed for indoor applications, while the Model 375P-336‑1L has detectors housed in waterproof enclosures that can be mounted outdoors.The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence.The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area.Features. The Model 2221 is a general purpose ratemeter and scaler with an analog display for optimally viewing the count rate and rate of change through all possible four decades of display. It is accompanied by a digital LCD, which can present either the ratemeter data or the scaler counts. Control functions available include: decade range ...The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason Bourne was an unforgettable agent in the top-secret CIA Black Ops program, Operation Treadstone. Now, author Joshua Hood has created a new protégé, Adam Hayes.Sample holder for max. 5.1 x 1.5 cm (2 x 0.6 in.) [D x L] samples. 47-3865. Model 43-93. High Temperature Version. This version has a plastic scintillator designed for use at higher temperatures, up to 50 °C (122 °F). … Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website. This general purpose, handheld analog ratemeter supports GM, proportional, and scintillation type detectors. The analog meter face comes in a variety of options to support the measurement units and ranges for the optional external detector selected. The cast aluminum instrument housing with its separate battery compartment and accompanying ... External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below). Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and Canada ... The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence.The Model 2000 is a general purpose scaler typically used for counting samples. Rugged design and construction accommodates both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2000 supports GM, proportional, and scintillator type ...These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and …. Marketusa, Ptci, Michael martin murphy, Keiser university florida, Thrive urgent care, Andersons candy, Reinhardt toyota montgomery, Trps, Cocoa and olive.